DON'T BLOCK AIR CIRCULATION IN YOUR SYSTEM!

Experience Meets Innovation: Your Trusted DC Blower Fan Manufacturer

Maximize Your Product Air Circulation Efficiency with CCHV DC Blower Fans!

Manténgase adelante con nuestra innovación
DC Blower Fan Designs

CCHV designs and manufactures a wide range of DC blower fans, offering sizes from 20mm to 120mm and voltages of 3V, 5V, 12V, 24V and other custom voltages. Our DC blowers, featuring hydraulic & ball bearings and IP55 ratings, are customizable for various industrial needs, backed by a in-house and experienced R&D team. Choose us for the perfect blend of high performance, energy efficiency and cost effective!

Voltajes

5V, 9V, 12V, 24V, 48V
u otros voltajes requeridos

Rango de tamaños

20mm-250mm

Tipos de rodamientos

Hidráulicos y de Bolas Dobles

IP Grade

IP21-IP55

Normal DC Blower

20x20x6mm, 30x30x10mm, 40x40x10mm, 40x40x15mm, 45x45x10mm, 50x50x15mm, 50x50x25mm, 53x53x9mm, 60x60x23mm, 60x60x25mm, 60x60x28mm, 70x70x28mm, 75x75x30mm, 75x75x50mm, 90x90x15mm, 97x97x33mm, 100x100x26mm, 120x120x32mm

50X50X10mm

Velocidad Máx.: 6200RPM
Flujo Máximo de Aire:
3.89 CFM
Presión Máxima del Aire: 20.13 mmAQ

50X50X15mm
Series B

Velocidad máxima:
6700RPM
Flujo Máximo de Aire:
5.13 CFM
Presión Máxima del Aire:
28.40 mmAQ

75X75X30mm
Series D

Velocidad máxima:
5300RPM
Flujo Máximo de Aire:
18.47 CFM
Presión Máxima del Aire:
30.53 mmAQ

97X97X33mm
Series B

Velocidad máxima:
6400RPM (24V)
Flujo Máximo de Aire:
47.12 CFM
Presión Máxima del Aire:
94.88 mmAQ

Other DC Blowers

High Speed DC Blower

60x60x25mm

70x70x28mm

75x75x30mm

Ø100X25mm
DC Centrigual Fan

Max. Speed: 4300RPM
Flujo Máximo de Aire:
39.70 CFM
Max. Air Pressure: 15.70 mmAQ

60X60X25mm
Series H

Velocidad máxima:
12000RPM
Flujo Máximo de Aire:
22.46 CFM
Presión Máxima del Aire:
145.94 mmAQ

70X70X28mm
Series B

Velocidad máxima:
9000RPM
Flujo Máximo de Aire:
29.97 CFM
Presión Máxima del Aire:
109.74 mmAQ

75X75X30mm
Series G

Velocidad máxima:
8200RPM (24V)
Flujo Máximo de Aire:
34.28 CFM
Presión Máxima del Aire:
107.16 mmAQ

Be carefully when you choose a new fan supplier. The La decepción de baja calidad dura mucho más que la Dulzura del PRECIO BAJO!

¡Escríbanos hoy! Nuestros ingenieros experimentados se pondrán en contacto con usted dentro de 6 horas.

Sistemas de rodamientos

Bearing system is the “heart” of DC Blower fans, which, to a large extent, determines the fan lifespan. There are mainly two types of bearings at CCHV. The following descriptions and comparisons can help you to get your right bearing system for your applications. 

Rodamiento hidráulico/de rifle

El rodamiento hidráulico/de rifle es una actualización del rodamiento de manguito común, que tiene ranuras de retorno para el aceite lubricante para resolver Problema de fugas. Tanto los rodamientos hidráulicos como los de manguito son cuerpos sinterizados hechos de polvo de cobre y hierro a través de la metalurgia.

Rodamiento de Bolas Doble

Ball bearing is a kind of rolling bearing, the spherical alloy steel ball installed in the middle of the inner ring and the outer ring, in a rolling way to reduce the friction in the process of power transmission and improve the efficiency of mechanical power transmission.

Ball-Bearing-1024x682-1.jpg

 Rodamiento de Bolas Doble 

Montaje en motor

Base del eje y tubo medio del marco

Después de determinar qué tipo de rodamiento es su opción perfecta, aquí puede encontrar información adicional sobre el diseño de la estructura del ventilador para ayudarlo a maximizar el rendimiento del ventilador. 

Tipo Económico

El tipo normal de base del eje y tubo central del marco están hechos de plástico, como se muestra en las siguientes imágenes, que se utiliza con cojinete hidráulico cuando el ventilador funciona a baja velocidad bajo temperatura normal.

Высоконадежный тип

High reliable type of shaft base and frame middle tube are made of pure copper as the following picture. Copper base and copper tube gets more accurate and better cooling effect when operating at the high speed, which are normally used with dual ball bearing. 

Base de eje de plástico normal
Tubo de plástico
Base de eje de cobre
Copper Tube In Frame

Forma de onda de las funciones del CI

Diferentes funciones del circuito integrado pueden ayudarle a saber cómo funciona el ventilador bajo qué estado. La función PWM puede mejorar la eficiencia energética del ventilador mediante el control de la velocidad. Aquí puede encontrar las formas de onda de diferentes funciones del CI. 

Señal del detector de rotación / Señal de alarma

RD signal is used to detect whether the fan is running or not. When the fan is normally running, the output level is low, whereas, high output level means the fan is stopped. 

Señal del Generador de Frecuencia (FG) / Sensor de Velocidad

FG Signal, as known as Tacho Signal,  is to provide a square wave signal from the fan, and the signal frequency represents the speed of the fan, which means FG conveys speed info in the form of square waves and normally it works with PWM.

Control PWM

The fan speed can be controlled by Pulse Width Modulation. PWM periodically outputs the voltage at a certain time, which is called the duty cycle, usually expressed as a percentage.

Boost Your Product Performance with Custom-made DC Blower Fans

Elevate your products with customized DC blowers fans from CCHV, tailored to your industry’s specific needs. Our versatile DC Blower Fans optimize efficiency in various industries. Our R&D team crafts innovative solutions that keep you ahead of the competition. Experience the difference of partnering with us for custom-made and high-performance DC Blower Fans designed for your success.

Industrias a las que podemos servir:

Por qué elegir CCHV

Since 2006, CCHV has specialized in developing and manufacturing high-quality DC Blower Fans. Our expert R&D team and advanced testing equipment enable us to create custom-made solutions for diverse industries. With 17+ year experiences, CCHV is qualifed to be one of China top DC blower fan manufacturers. Partner with us for exceptional ventilation solutions that cater to your specific needs. 

Países exportadores
0 +
Clientes satisfechos
0 +
Marcas atendidas
0 +

Revolutionize Your Air Circulation Solutions
con nuestro equipo especializado de I+D

Guided by a seasoned manager with a decade of experiences in Taiwan’s fan industry, our dedicated divisions work cohesively to deliver customized, high-performance DC blower fan solutions for various industries. Benefit from our expertise in flow analysis, electromagnetic simulation, vibration research and acoustic analysis and Utilize our state-of-the-art testing equipment to ensure product reliability and stability. 

Análisis de flujo

El análisis de flujo ayuda a identificar los ángulos óptimos entre los impulsores móviles y estacionarios para mejorar la eficiencia aerodinámica y reducir el ruido del ventilador.

Motor Research

La simulación electromagnética se utiliza para diseñar el número de polos de ranura para determinar la mejor forma del motor del ventilador para optimizar la eficiencia del motor.

Análisis de vibraciones

El análisis de vibraciones se utiliza para encontrar la frecuencia resonante para optimizar la estructura del ventilador con el fin de resolver el problema de resonancia después del montaje del ventilador.

Investigación Acústica

Sound quality analysis helps to reduce sharp and other unpleasant audio in order to give users the most conformtable sound experiences.

Uncompromising Quality: The Benchmark of Our DC Blower Fans

La calidad es nuestra principal prioridad, la cual sostiene nuestro desarrollo en los últimos 17 años. Como fabricante certificado IATF16949, nos enfocamos en la prevención, no solo en la inspección. Desde los materiales entrantes, la fabricación hasta el ventilador terminado, implementamos un control de calidad estricto de acuerdo con el principio VDA6.3.

Ver para creer: Raramente implementado por nuestros competidores.

Código QR para trazabilidad.
Prueba de vibración
Prueba de envejecimiento a temperatura ambiente
Prueba de envejecimiento a alta temperatura (en horno)

Siempre manteniendo la sonrisa como nuestros clientes felices

Como Ingeniero Mecánico Senior en USA, estoy impresionado con las capacidades de I+D y el servicio personalizado de CCHV. Su equipo experimentado comprendió nuestras necesidades únicas de refrigeración y entregó justo lo que necesitábamos. ¡Gran trabajo, CCHV!

Thomas Johnson Ingeniero Mecánico Senior

Soy gerente de proyecto en India. ¡Asociarse con CCHV ha sido un cambio radical! Sus ventiladores de CC personalizados son muy confiables y perfectos para nuestros proyectos de almacenamiento solar. Su rápida respuesta y apoyo profesional han hecho que nuestros proyectos se ejecuten sin problemas. ¡CCHV es nuestro proveedor principal!

Rajesh Sharma Gerente de Proyecto

Soy especialista en adquisiciones en Italia. ¡Trabajar con CCHV ha sido un placer! Entregan ventiladores de refrigeración de CC de primera calidad que cumplen perfectamente con nuestros requisitos de UPS. Su servicio receptivo y envíos puntuales hacen mi trabajo como especialista en adquisiciones mucho más fácil. ¡Altamente recomendado!

Isabella Rossi Especialista en Adquisiciones

FAQ

Preguntas Frecuentes

Estas son las preguntas más frecuentes. Si no puede encontrar una respuesta aquí, por favor contáctenos por correo electrónico en [email protected] 

Para una preparación precisa de la cotización, por favor indique el tamaño del ventilador, el voltaje, el flujo de aire, las funciones del cable conductor, el tipo de conector y dónde se utilizará el ventilador. El tamaño del ventilador, el voltaje y dónde se utilizará son información necesaria para obtener.

Tenemos dos tipos de rodamientos, hidráulico y de doble rodamiento de bolas. El hidráulico también se llama rifle con 30000 horas a 40 grados. Y para el ventilador de doble rodamiento de bolas, la vida útil es de 50000 - 70000 horas a 40 grados, lo cual también está relacionado con el diseño de la estructura del motor.

IP21 for simply damn-proof; IP55 with PCB coating or potting; IP68 with the whole stator potting.

Para el ventilador IP54, puede pasar la prueba de 96 horas según el requisito normal del cliente; para IP55, puede pasar la prueba de 10 días; para el ventilador IP68, puede pasar la prueba de 30 días.

Para 5 piezas o menos de muestras gratuitas, normalmente se tarda 7 días laborables y para 10 piezas o más muestras, tomará de 10 a 14 días. 

Normally 1000pcs/fan type. Hundreds of pieces as trial run are acceptable before launching mass productions. 

Production lead time is 25-30 days. 

¡SOLICITE UN PRESUPUESTO AHORA!

¡RESPONDER DENTRO DE 12 HORAS!

Obtén GRATIS Samples For Your Customized DC Blower Fan Solutions Today

If you need help to find the right dc blower fan solutions for your systems or devices, we’re here to support.

Let us know how we can help, and we’ll in touch with the information you need to select the most suitable DC Blower Fans within 12 hours.

Contact us today and get started on a better way to keep your systems or devices work properly without air circulation problem!

Need Reliable DC Fans Tailored To Your System?
Look no further, Let's chat!

Just leave your name, email and simple messages or requirements, we’ll be in touch with you within 12 hours.

Need Immediate Discussions?

Please call or whatsapp Annie at +86 13538992575.

Hey, need support to get the right fan solutions?

We're HERE TO ASSIST YOU!

Just spend a few seconds to fill up with your name and email and you can expect our professional feedback and FREE SAMPLES!

Want to get GRATIS samples for testing?

We're HERE TO ASSIST YOU!

Contact us now if you need help to get the right fan for your cooling solutions. We’ll in touch with you within 6 hours.